gtech.com.vn
  
 

FD700DL+ Flaw Detector

Bookmark and Share

Mô tả


With all the functionality of the top of the range material thickness gauge, the FD700DL+ flaw detector, when in flaw detection mode offers a variety of tool kits which enable fast and accurate flaw detection, ideal for weld inspection, forgings or composite material testing.

Tool kits include:

  • TRIG enabling location of flaws in both surface distance and depth from the transducer.
  • DAC for the creation of DAC curves which are used to inform the operator of the size of any given flaw at any depth.
  • AWS function provides automatic defect sizing in accordance with AWS D1.1 structural welding code.
  • AVG/DGS allows automatic defect sizing using probe data, storing up to 64 custom setups.
  • TCG (time corrected gain) increases gain as time increases, in order to achieve an over all level of sensitivity for the same flaw/reflector at different distances.

Advantages

  • Exceptional visibility in sunlight (AMOLED) colour VGA display (320x240 pixels)
  • Sizing Toolkits: DAC, AWS, TCG, DGS
  • P.R.F. 8 to 333 Hz, adjustable
  • Screen Refresh Rate: Adjustable 60 & 120 Hz
  • Detection: Z-Cross, Flank & Peak
  • Automatic: probe zero, probe recognition, and temperature compensation
  • Measurement: Variety of modes to address a number of applications
  • Large data storage with multiple formats: Alpha numeric grid and sequential w/auto identifier
  • Up to 12 hours of battery life
  • Data management software
FD700DL+-flaw-detector

Đặc điểm kỹ thuật

 
Model & Part Number FD700DL+ Flaw Detection Gauge
Material thickness digits display
B-Scan cross sectional display
B-Scan with digits display
Scan bar display
Coating thickness display
A-Scan display + Rectified, - Rectified, Full Waveform (RF) 
Flaw detection modes TRIG, DAC, AWS, TCG, Zero Crossing, Flank, Peak 
Measurement Mode PE, PETP (Temp Compensation),
EE (ThruPaint™), EEV, CT (Coating) & PECT
Measurement Rate (Thickness Mode)
Manual:
Scan mode
Scan bar display

4 readings per second
32 readings per second
6 readings per second
Measuring Range PE: 0.63 - 30480mm (0.025 - 1,200 inches)
PETP: 0.63 - 30480mm (0.025 - 1,200 inches)
EE: 1.27 - 102mm (0.050 - 4.000 inches)
EEV: 1.27 - 25.4mm (0.050 - 1.000 inch)
CT: 0.01 - 2.54mm (0.0005 - 0.100 inch)
PECT: 0.63 - 30480mm (0.025 - 1,200 inches)
PECT: 0.01 - 2.54mm (0.0005 - 0.100 inch)
Measurement Accuracy ±0.01mm (±0.001 inch)
Measurement Resolution 0.01mm (0.001 inch)
Velocity Calibration Range 256 - 16,000m/s (0.0100 - 0.6300in/ms)
Additional Features:  
    High speed scan mode
    Differential mode
    Limit alarm mode
B-Scan display speed adjustable display speed
Calibration setups 6 factory & 64 user-definable setups
transferrable to and from a PC archive
Gates 3 fully adjustable gates:
start, stop, width & threshold
Damping adjustable; impedance matching for
optimising transducer performance
Pulser type dual 200 Volt square wave pulsers with
adjustable pulse width (spike, thin, wide)
and 50 Volt cut/boost for greater penetration
Gain manual, automatic gain control (AGC)
with 110dB range with 0.2dB resolution
Timing precision 25MHz TCXO with single shot
100MHz 8bit ultra low power 8 bit digitizer
Data logging • 8,000 with A/B-scan image & gauge settings
• 210,000 - coating, material, min, max thickness
• sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
Calibration Options single, two point, velocity & material type
Transducer recognition automatic
V-path / dual path error correction automatic
Probe zero automatic
Flaw Detection Mode Features
Automatic
Calibration:
Longitudinal (straight),
or Shear (angle)
Probe Types: Single Contact, Dual, Delay & Angle
Material Velocity Table: Contains longitudinal and shear
velocities for a variety of material types
TRIG Trigonometric display of beam path,
depth, surface distance, and curved surface correction.
Used with angle beam transducers
DAC Up to 8 points may be entered and used to digitally
draw a DAC curve. Reference -2, -6, -10, (-6/-12),
(-6/-14), (-2/-6/-10) dB. Amplitude displayed in
%DAC, dB, or %FSH
AWS Automatic defect sizing in accordance with AWS
D1.1 structural welding code.
AVG/DGS Automatic defect sizing using probe
data. Stores up to 64 custom setups
TCG Time corrected gain. 50 dB dynamic range, 20 dB
per microsecond, up to 8 points for curve definition
Detection Modes Zero Crossing, Flank and Peak
Display Freeze Hold current waveform on screen
Peak Memory Captures peak signal amplitude.
P.R.F 8 to 333Hz in selectable steps (8, 16, 32, 66, 125,
250, 333Hz)
Pulse Width 40 to 400 ns. Selectable step
options 40, 80 & 400 ns (labeled spike, thin &
wide)
Frequency Bands FD700+ & FD700DL+: Broadband 1.8 - 19 MHz
(-3dB). FD700DL+: Three
narrow bands at 2MHz, 5MHz, 10MHz
Horizontal Linearity +/- 0.4% FSW
Vertical Linearity +/- 1% FSH
Amplifier Linearity +/- 1 dB
Amplitude Measurement 0 to 100% FSH, with 1% resolution
Delay 0 - 999in (25,375mm) at steel velocity
Display 1/4" VGA AMOLED colour display
57.6 x 43.2mm (2.27 x 1.78inch)
viewable area
Display Refresh Rate 120Hz
Units (selectable) mm or inches
Backlight adjustable brightness
Repeatability / Stability Indicator
Battery Type 3 x AA alkaline
Battery Life
(approximate)
12 hours
Low Battery Indicator
Battery Save Mode auto
Operating Temperature -10 to 60ºC (14 to 140ºF)
Size (w x h x d) 63.5 x 165.0 x 31.5mm
(2.5 x 6.5 x 1.24 inches)
Weight (including batteries) 397g (14oz)
Case Design Aluminium case design with gasket sealed end
caps, waterproof membrane keypad
Transducer Connector Type LEMO
RS232 Interface Bi-directional
Packing List Elcometer FD700DL+ gauge,
couplant, carry case, user manual, test certificate, 